Site Search: "treatment"

Displaying search results from 53 results are found

PRODUCTS


CONTENT

AirSense 10 Elite Supplier. To navigate through non-complicated settings and menus, just start and press the button to go hunting. The integration of this device in the HumidAir ™ (Humidifier), a more comfortable experience and convenient temperature and humidity retention tube automatically work.

A comfortable start! (AutoRamp) If you have a sleeping problem, go for them with low pressure cushioning too. AutoRamp starts with low pressure for more comfortable sleep.

Built-in ambient light sensor !! The light level of the screen is based on the brightness of the environment. Bring your keyframe to the screen. The screen light shuts off at night so as not to disturb the more comfortable sleep.

Other Features

The Easy-Breathe engine is quieter than you and your partner whisper, offering more peaceful night's sleep.
The simple and intuitive user interface provides feedback on morning treatment and it is much easier to change settings.
User-friendly controls make it easier for you to navigate and customize the menus with the color LCD display.
The SmartStart ™ function initiates the therapy with breathing into the size mask as soon as possible. If you just remove the dick, stop in a few seconds.
Integrated HumidAir ™ humidifier with Climate Control technology and optional ClimateLine (thin hose) Long lasting humidification with air heated tube.
How to use?

Here are some tips on setting up the site;

The therapy system most likely consists of a mask, a tube, a therapy device, and a moisturizer. Translate for all sections. Knowing how to set up equipment and equipment does not make you different for your treatment!

SOME TIPS IN RESMED:

First, make sure you place it on a specific surface. Do not put your business into luck.
When you sleep in your bed, put it in a place where you can reach the auditors.
If the device is empty, someone does not cover it with the cover, keep it away from materials such as walls, heaters.

Detail

Reslex - Expansion Comfort

Respirox CPAP also offers exclusive reslex technology, which allows the patient to have better respiratory comfort, reducing pressure on the outside, and allowing the patient to spend less effort during sleep.

 

Reslex Feature

It is the ability to throw excess pressure out of the patient without exposing the patient during expiration, minimizing effort. This feature minimizes the causes of heart rhythm disturbances in patients. The goal is to get the rest of the day away from the pressure of the patient, while allowing the patient to have a comfortable night's sleep. In order to activate Reslex feature, user login must be done from the menu.

iCode Feature

The ability to save users' data. The Respirox CPAP device records data for 365 days. is an advanced technology that allows patients to see the time they have used before and the AHI (apnea, hypopnea) indices.

* The length of time the patient has used

* Device, mask, patient compliance

* AHI (apnea hypopnea) indices

* Average pressure

* Mask escapes

It keeps the user visible and keeps it in memory for 365 days. When the data storage is full, it saves the last day and deletes the day that it was first used, so you can see your current data whenever you want.

Auto User Features

* Respirox devices are equipped with a breathing sensor, without any trouble to press any key before the auto-opening feature of the device by removing the mask and auto-off feature is enabled. this feature can be activated and disabled from the menu.

* In heavy mask leakage, the device switches to alarm position and warns the user.

* Automatically adjusts the altitude level of the area you are in.

* If the power is turned off while the device is in operation, an automatic alarm is activated and warns the user.

Heater Humidifier Features

Respirox devices can optionally be integrated in the heater humidifier to adjust the temperature setting of the incoming air to the user in 5 steps.

With a lid guard designed to prevent water from escaping into your device, it allows you to use your device comfortably during the night. With a heating feature between 1-5, it allows the patient to have a comfortable night's sleep without being exposed to cold weather during sleep.

Smart Phone Application

To download free software (3B / BMC iCode) for Respirox devices, you can view your data anywhere and anytime using your iPhone and Android devices, iTunes and GooglePlay.

TECHNICAL SPECIFICATIONS :
Dimension: 22cm * 19,4cm * 11,2cm
Weight: 2.0 kg
Power requirement: 230 VAC, 50 Hz
Reslex: 3 step
Pressure range: 4-20 cmH2 °
Heater humidifier: (optional)
Noise level: 24dBA
365 days to record data
Ramp time: 0-60 minutes
Automatic altitude setting: 4 stages
Auto On / Off
Treatment counter
Automatic air leak compensation
Detailed data recording
iCode feature
Usage hour report
Alarm: Power failure, mask and hose leak alarm
Approved by Ministry of Health CE and ISO Certified

Detail

Respirox Auto AUTO CPAP Device Automatic Pressure Setting Technology and Sensitivity Setting Reslex feature iCode Remote Advanced Data Recording Data Recording 365 days Auto Swich feature (auto on / off) Auto Altitude setting Alarm feature Emergency warning 5 stage Integrated heater humidifier For easy transportation holding line Min - Max 4 cmH2O / 20 cm H2O pressure range

Reslex Feature

It is the ability to throw excess pressure out of the patient without exposing the patient during expiration, minimizing effort. This feature minimizes the causes of heart rhythm disturbances in patients. The goal is to get the rest of the day away from the pressure of the patient, while allowing the patient to have a comfortable night's sleep. In order to activate Reslex feature, user login must be done from the menu.

iCode Feature

The ability to save users' data. The Respirox CPAP device records data for 365 days. is an advanced technology that allows patients to see the time they have used before and the AHI (apnea, hypopnea) indices.

* The length of time the patient has used
* Device, mask, patient compliance
* AHI (apnea hypopnea) indices
* Average pressure
* Mask escapes
It keeps the user visible and keeps it in memory for 365 days. When the data storage is full, it saves the last day and deletes the day that it was first used, so you can see your current data whenever you want.

Auto User Features

* Respirox devices are equipped with a breathing sensor, without any trouble to press any key before the auto-opening feature of the device by removing the mask and auto-off feature is enabled. this feature can be activated and disabled from the menu.

* In heavy mask leakage, the device switches to alarm position and warns the user.

* Automatically adjusts the altitude level of the area you are in.

* If the power is turned off while the device is in operation, an automatic alarm is activated and warns the user.

Heater Humidifier Features

Respirox devices can optionally be integrated in the heater humidifier to adjust the temperature setting of the incoming air to the user in 5 steps.

With a lid guard designed to prevent water from escaping into your device, it allows you to use your device comfortably during the night. With a heating feature between 1-5, it allows the patient to have a comfortable night's sleep without being exposed to cold weather during sleep.

Smart Phone Application

To download free software (3B / BMC iCode) for Respirox devices, you can view your data anywhere and anytime using your iPhone and Android devices, iTunes and GooglePlay.

TECHNICIAL SPECIFICATIONS :

Dimension: 22cm * 19,4cm * 11,2cm
Weight: 2.0 kg
Power requirement: 230 VAC, 50 Hz
Reslex: 3 step
Pressure range: 4-20 cmH2O
Heater humidifier: (optional)
Noise level: 24dBA
365 days to record data
Ramp time: 0-60 minutes
Automatic altitude setting: 4 stages
Auto On / Off
Treatment counter
Automatic air leak compensation
Detailed data recording
iCode feature
Usage hour report
Alarm: Power failure, mask and hose leak alarm
Approved by Ministry of Health CE and ISO Certified

Detail

AirSense 10 AutoSet is a self-regulating pressure therapy device that automatically adjusts pressure levels to suit your needs and to ensure you get the lowest pressure you need. When AirSense 10 AutoSet ResMed is used with the new Humidair heated humidifier and the ClimateLineAir heated tube, it offers the most comfortable temperature and humidity levels.

Key Features

Intelligent detection: With sleep-on detection AutoRamp starts by offering low pressure for extra comfort and after sleeping, gradually boosts pressure to the predicted level.

Just press the start key and get ready!

Simple and intuitive user interface provides feedback about treatment every morning. It is now easy for you to change the comfort settings with this interface.

Other Features

Built-in ambient light sensor; The light level of the display is automatically adjusted according to the brightness of the room. If you need to get up all night, the back of the screen will not spoil your partner and your comfort.
The Easy-Breathe engine provides you and your partner with a more peaceful night's sleep.
When the SmartStart function is masked, sleep apnea therapy begins with breathing. If you remove the dock, the unit automatically stops after a few seconds.
Increased comfort and consistent dampening throughout the night with the integrated Humidair ™ humidifier. Climate Control technology provides ultimate comfort, controlled heated tubing, and optional ClimateLineAir provides complete comfort.
How to use?

Here are some tips on setting up equipment; The therapy system most likely consists of a mask, a tube, a therapy device, and a moisturizer. You only need to navigate the therapy menu to set all the parts to detect. Having information about all equipment for your treatment and making the adjustments correctly will make your treatment much easier.

Here are some tips from ResMed:

First, make sure that you place the device on a stable, flat surface without covering it over. Do not put your business into luck.
Put your device in an accessible position for inspections when lying in your bed.
Do not cover the device with any blank, keep it away from materials such as walls, heaters, etc.

Detail

PERFORMANCE CHARACTERISTICS RESPIROX BiPAP S DEVICE

Automatic Pressure Setting and Sensitivity Setting

Reslex feature (Pressure Reduction)

ICode Remote Advanced Data recording

Data recording 365 days

Auto Swich feature (auto on / off)

Auto Altitude setting

Alarm feature

Air leak warning

5 stage Integrated heating humidifier Handle for easy handling

EPAP - IPAP Working between 4 cm HO2 / 30 cm HO2

Four modes: CPAP, Spontaneous (S).

AUTOMATIC PRESSURE ADJUSTMENT AND SENSITIVITY ADJUSTMENT FEATURES

Pressure adjustment depending on the position of the bed, measuring the most appropriate pressure to the patient.

Instant response to precise pressure changes with a pressure range of 0.5 - 1.

The sensitivity can be adjusted according to the needs of the patient between 1-5 so that they can breathe without giving the patient with a smooth usage.

RESLEX FEATURE

It is the ability to throw out excess pressure by expending a minimum effort without exposing the patient during expiration. The goal is to get the rest of the day away from the pressure of the patient, while allowing the patient to have a comfortable night's sleep. To enable the Reslex feature, a menu entry must be made.

iCODE FEATURE

The ability to save users' data. Respirox Bpap ST records data for 365 days. It is a sophisticated technology that allows patients to see the time they have used before and the AHI (apnea, hypopnea) indices.

* The length of time the patient has used

* Device, mask, patient compliance

* AHI (apnea hypopnea) indices

* Average pressure

* Mask escapes

It keeps the user visible and keeps it in memory for 365 days. When the storage is full, it saves the last day and deletes the day it was first used, so you can see your current data every time you want.

AUTOMATIC USER FEATURES

* Respirox devices are equipped with a breathing sensor, without any trouble to press any key before the auto-opening feature of the device by removing the mask and auto-off feature is enabled. This feature can be activated and disabled from the menu.

* In heavy mask leakage, the device switches to alarm position and warns the user.

* Automatically adjusts the altitude level of the area you are in.

* If the power is turned off while the device is in operation, an automatic alarm is activated and warns the user.

HEATER HUMIDIFIER FEATURES

Respirox devices can optionally be integrated in the heater humidifier to adjust the temperature setting of the incoming air to the user in 5 steps.

It is designed to prevent water from escaping into the device, allowing you to use your device easily during the night.

With a heating stage of 1-5, the patient can get a comfortable night's sleep without exposure to cold weather during sleep.

For more information about iCode functions, you can view the Respirox iCode Quick Reference Form.

SMART TELEPHONE APPLICATIONS

To download free software (3B / BMC iCode) for Respirox devices, you can view your data anywhere and anytime using your iPhone and Android devices, iTunes and GooglePlay.

TECHNICIAL SPECIFICATIONS :

• Respiration rate (Res. Rate)

• Measure: 22cm * 19,4cm * 11,2cm

• Weight: 2,0 kg

• Power requirement: 230 VAC, 50 Hz

• Reslex: 3 step

• Pressure range: 4-30 cmH2 °

• Heated humidifier: (Optional)

• Noise level: 24 dBA

• Can record 365 days of data

• Ramp Time: 0-60 minutes

• Automatic altitude setting: 4-stage

• Auto On / Off

• Treatment counter

• Automatic air leak compensation

• Detailed data recording

• iCode feature

• Usage hour report

• Alarm: Power failure, mask and hose leakage alarm

• Adjustable trigger and speed indicator

Detail

The CPAP device is silent and easy to carry, with a short treatment time and constant pressure; The SGK is an affordable device for contracting your sleep apnea and other disabilities with the possibility of negotiable price-fixing.

Detail

From the first day on, we have been in the best treatment for chronic respiratory diseases. When the disease strikes, the families react tightly as a united whole. As a whole, they are tormented by a loved one's disease. And as a whole, the families share in the joy of recovery. At BMC, we believe families are at the heart of health. Supported by science, they force the burden of disease together. And it is our job to help combine this priceless human touch with technology.

Detail

The patient should have spontaneous breathing, but the breathing frequency should be adjustable by the device. The BPAP ST should be tried in cases where BPAP does not enter the respiratory tract, treatment is required at higher pressure, and especially in the presence of central apneas. In patients with obstructive sleep apnea syndrome as well as pathologies leading to alveolar hypoventilation such as restrictive pulmonary disease, COPD, obesity-hypoventilation syndrome, sleep-related hypoventilation / hypoxemic syndrome, it may be advisable to use spontaneous respiration and determination that the triggering power is insufficient.

Detail

The most important and most important criterion in mask selection is the type of mask the doctor recommends. For effective treatment, you should choose the mask type recommended by your physician. There are several different mask types available. These are: Nasal Mask Nose Padded Mask Ora-Nasal Mask Oral Mask All Facial Mask Nasal Cannula

Detail

Oxygen concentrator devices are molecular sieves, which separate gases from ambient air and produce oxygen at 95% (± 3) purity. Molecular sieves can be used to produce industrial oxygen concentrators, as well as devices that provide oxygen-friendly oxygen gas for treatment of COPD and similar chronic respiratory disorders. Oxygen concentrators are used at home or in the hospital for treatment of many respiratory diseases.

Detail

Elifce Medical Health Services carries out the test for the detection of sleep diseases with serious negative effects on health and quality of life at the patients' home.
The sleep test is the recording and evaluation of all night sleep according to various parameters in order to make the diagnosis of many sleep diseases and accordingly to make accurate and effective treatment planning.
A home sleep test is carried out in an environment in which the patient is accustomed to sleep, feels comfortable and can perform his / her activities before bedtime.
In the home sleep test, the electrodes and sensors connected to certain parts of the body record the sleep stages, cycle, sleep mobility and body functions. The data obtained are evaluated by our specialist doctor and diagnosed.
Please click here to fill out the Sleep Diseases Information Form

Detail

With the experience of the Central Hospital, you can perform a sleep test safely in your natural sleep without having to go into hospital stress on your own bed with a mobile polysomnography device. You can learn the causes of your sleep problem through this test and plan your treatment.

Detail

It is important to clean your equipment as specified in the product instructions. Failure to do so properly may reduce the effectiveness of your sleep treatment and cause damage to your equipment.
 
Do not use alcohol or cleaning solutions when cleaning masks, nasal pads or circuits. Otherwise, these parts may be damaged. Use only warm soapy water.
 
Daily cleaning
Mask:
- Remove the mask / nasal pads from the cap.
- Clean with warm soapy water. Rinse.
- Let it dry.

Circuit:
- Wash in warm soapy water, rinse and allow to dry.
 
Moisturizer:
- Empty the humidifier and let it dry. Replace the water in the humidifier. Always use distilled water in the humidifier to prevent deposition of mineral debris.
 
Weekly cleaning
Filter: Clean the gray / black foam filter on your machine with warm soapy water. Rinse. Let it dry. Reinsert.
 
Headgear: Wash head with hand using warm soapy water. Rinse and leave to dry.
 
Device: Wipe the device with a soft, damp cloth.
 
Moisturizer: Clean the humidifier chamber with white vinegar to prevent mold. Be sure to rinse thoroughly with distilled or sterile water before using the humidifier.
 
Monthly cleaning
Filter: Replace the replaceable white filter (if applicable).

Detail

In order to purchase a device from the Social Security Institution;

First of all, you need to apply to SSI Directorate. The organization will give you the device specified in your report from its own inventory. However, if there is no equipment in stock for the institution, you will be able to purchase the device from the medical distributor and receive a refund from the institution pursuant to Article 7.2.2 of the SUT (Health Implementation Communiqué).

Documents required for reimbursement;

  • The report or your prescription must include 'No organization' approval.
  • UBB (National Knowledge Base) registration of the device.
  • Warranty Certificate of the device.
  • Proof of Entitlement for the company from which you purchased the device.
  • A commitment to return the device to the institution at the end of the treatment.
  • UBB tag (Barcode) of the device.
  • Company UBB Registration.
Detail

1. Which unit should be visited in the Social Security Institution?
Answer: You need to go to the Returned Devices Service connected to the SGK Directorates with your reports and documents. The Service inspects your documents and delivers the device in stock without a fee request. However, institutions do not interfere with the consumables of the devices (masks, hoses, filters, etc.).

2. Does the SSI give a new device?
Answer: The devices you have received by SGK are not zero. Because SSI does not buy new devices. Previously used devices are returned to the patients are given again.

3. Does the device I purchased belong to me?
Answer: If you have to buy the device because SGK is not in stock, you have to return the device to SGK at the end of the treatment if you get the institution repayment. Even if you have paid a difference to the device you have purchased the device you receive payment from the institution you are embezzled and the institution belongs. There is no proportion of the difference amount you have paid. You shall bear all the difference fee above the corporate payment amount specified in the Health Implementation Communiqué.

4. When and how does the SSI pay back?
Answer: The amount of the repayment of SGK device within 20 - 45 days. Ziraat Bank T.C. Your ID is deposited in your number.

5. How long is the prescription validity period?
Answer: You must apply to the institution within 13 days after your prescription is written.

6. Where will I take the device in case of technical failures related to the devices?
Answer: In the technical problems related to the device you have used, you should first bring the device to the institution. If the technical service of the institution cannot be intervened, you must contact the technical service of the manufacturer.

7. Who is paying for the service charge when the device is sent to technical service outside the scope of the warranty?
Answer: SGK service fee is up to 1.000 TL. If the service fee above this amount, the institution does not accept this fee, the device is scrapping and giving the new device to the patient.

8. What should I do when there is a power failure in the treatment of the oxygen concentrator, which is constantly used?
Answer: You will need to have an oxygen cylinder as an alternative to power outages.

Detail

NEWS

Sleep apnea test is the most important step in the process of diagnosis and treatment of the disease. A sleep apnea test called "polysomnography" is a test that records brain activity and respiratory events throughout the night.   Polysomnography, a sleep apnea test, is based on the measurement of bra
Detail

The sleep apnea can be prevented by simple things to take. The most important of the interchangeable risk factors for the disease is obesity. Sleep apnea can be reduced by 50%. In addition, avoiding alcohol and sleeping pills, quitting smoking and not lying on the back also reduce the inconvenience. Sprays or elastic bands th
Detail

Obesity, which should be done first in the treatment of sleep apnea, is to be overcome. If there are significant anatomic strictures in the upper respiratory tract, the patient should be evaluated for surgical intervention by an Ear Nose Throat specialist.  Progressive airway pressure (CPAP) therapy should be u
Detail

The respiratory device, also called the ventilator, is used in the treatment of chronic respiratory insufficiency. Long-term mechanical ventilation at home is very important in the treatment of respiratory insufficiency. Breathing apparatus is widely used, especially in terms of chest wall and neuromuscular diseases. Two type
Detail

Cpap and BiPAP are respiratory devices used in patients with respiratory problems. BIPAP (Bilevel positive airway pressure) Continuous positive airway pressure (CPAP) These two devices are used for external breathing assistance. Respiratory devices can be used not only for ALS, but also for many
Detail

Sleep Respiratory Disease (Obstructive Sleep Apnea Syndrome) Recurrent respiratory disorders (apnea, apnea, hypopnea: hypopnea) develop as a result of obstruction of the throat during sleep.
It causes sleep interruption due to the complete interruption of breathing or a considerable decrease in sleep during s
Detail

Chronic insomnia lasts at least a month. Most sleeplessers worry about their sleep. However, it is wrong to link the entire sleep problem to sleep anxiety. A study has shown that patients with this type of insomnia may have sleep respiratory or abnormal muscle activity. A sleep specialist may be able to help resolve the cause
Detail

If you are sleeping worse during stressful periods, you are worried that your performance during the day will not be good. You can spend more time sleeping at night. This usually causes things to go worse. After a few nights, some things you did before you went to bed remind you of your sleeping problems. Wearing your pajamas
Detail

People with sleep apnea stop breathing during sleep. This can wake up dozens or even hundreds of times during the night. The duration of breathing may be as short as 10 seconds. Most patients do not remember waking up. A sleep test is needed to diagnose sleep apnea. Sleep-related breathing problems are most commonly seen in m
Detail

PSYCHOLOGICAL FACTORS Insomnia tendency: Some people have more insomnia than other people in stressful periods. Others respond to stress by headache or stomach pain. Knowing that the person is prone to insomnia and that it will not last too long is useful when you deal with it when you develop insomnia.
Persi
Detail

There are three main types of sleep apnea: Obstructive Sleep Apnea (OSA)
Central Sleep Apnea (CSA)
Mixed sleep apnea Obstructive Sleep Apnea (OSA)
Obstructive Sleep Apnea is the most common type of sleep apnea. The diagnosis of sleep apnea is 84%.
Obstructive sleep apnea; It is
Detail

Treatment options for your snoring depend on a number of factors, but the two key ones are these: Do you snore through your nose or through your throat?
Do you snore and have obstructive sleep apnoea (OSA)? 
At ResMed, we have solutions for throat snorers, as well as for throat snorers with sleep
Detail

CATAGORY

BPAP devices for treatment of upper respiratory tract and lung diseases | bpap device prices, bipap device losses, bipap device price, bipap device users, bipap device sgk, bpap device mask, home bipip device prices, bipap device usage, bpap device sgk, home respirator
Detail

AUTOMATIC BPAP devices for upper respiratory tract and lung disease treatment products | auto bipap, auto bipap, auto bipap, auto bipap prices, auto bipap, auto bipap prices, auto bipap nedir, auto bipap sgk
Detail

AUTO SV adjusts the ideal air pressure automatically to provide optimal treatment during the night. | AutoSV, sleep apnea, treatment, breathing, apnea, sleep apnea syndrome,
Detail

Prevents build-up in the mouth, nose and throat, keeps the moisture level constant throughout the treatment. | resmed turkey distributor, resmed sleep apnea device, resmed fairs, resmed cpap device price, respirox cpap price, respirox cpap device price
Detail

Sleep apnea masks are designed as face and nose masks to offer you the most comfortable sleep apnea treatment possible. | sleep apnea mask, nose mask, face mask, sleep apnea masks, resmed, respirox, sgk, Respiratory Mask SGK
Detail

Effective medical device sales service maintenance services for sleep apnea and treatment. | sleep treatment devices, sleep test, sgk contracted devices, sleep devices care, respiratory device care, sleep test at home
Detail

Cleaning recommendations for sleep apnea treatment equipment | device care, respiratory device care, care recommendations, respiratory mask care, Hygienic Appliance Care, Ozone Gas Hygiene Care
Detail